| Physical | Dimensions | 142mm diameter x 160mm | |
| Weight | 0.5 kg | ||
| Mounting | Pipe mounting 1.75 in (44.45mm) diameter | ||
| Material | LURAN UV stabilised black thermoplastic | ||
| Performance | Wind speed | Range | 0 to 60 m/s (116 knots, 134 mph) |
| Accuracy | ±2 % @ 12m/s | ||
| Resolution | 0.01 m/s | ||
| Threshold | 0.01 m/s (0.02 mph) | ||
| Response time | 0.25 sec | ||
| Wind direction | Range | 0 to 359º (no dead band) | |
| Accuracy | ±3º @12 m/s | ||
| Resolution | 1º | ||
| Response time | 0.25 sec | ||
| Outputs | WindSonic Option 1 | RS232 | |
| WindSonic Option 2 | RS232 RS422/RS485 NMEA 0183 |
||
| WindSonic Option 3 | RS232 RS422/RS485 Analogue 0-5V, 0-20mA or 4-20mA NMEA 0183 |
||
| Output rate | 0.25, 0.5, 1,2 or 4 outputs per second (Hz) | ||
| Parameters output | Polar wind speed and direction or U & V Vectors, anemometer status | ||
| Units | kt, m/s, km/h, mph, ft/min | ||
| Serial output format | Polar (speed and direction) UV (2 axis, signed speed) or Marine NMEA 0183 v3 sentence MWV |
||
| Serial output baud rate | 2400, 4800, 9600, 19200 or 38400 | ||
| click here for details of the default serial output | |||
| Power | Power requirements | WindSonic 1 & 2 | 5 to 30 V dc |
| WindSonic 3 | 7 to 30 V dc | ||
| From 5.5 mA @ 12 V | |||
| Start up time | <5 seconds | ||
| Environmental | Temperature | Operating range: -35ºC to +70ºC Storage range: -40ºC to +80ºC |
|
| Humidity | Operating range: <5% to 100% RH | ||
| Protection Class | IP65 | ||
| EMC | EN 61326: 1998 | ||
| Miscellaneous | MTBF | 15 years | |
| Warranty | 2 years | ||
| Quality system | Manufactured within ISO9001 quality system | ||
| The manufacturer reserves the right to amend the specification and therefore the information in this document may be subject to change | |||